Currency:

Honeywell Midas Sensor Cartridge - Boron Trichloride (BCl3), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr), Hydrogen Chloride (HCl) 0.72-8 ppm


Require Install, Commissioning, Calibration or Servicing?

Safety Gear Store are able to install, commission and service your fixed gas detection system. We offer a professional service from fully trained, certified and manufacturer approved engineers, we are also one of the only suppliers with engineers that carry spares in their vehicles to ensure a quick and efficient service that will enable you to continue using your facility.For more information on what we offer please visit one of the below pages:

Fixed Gas Detection System Install and Commissioning

Fixed Gas Detection System Calibration and Servicing

Gas Measured:Hydrogen Chloride (HCI)
Part No.:MIDAS-E-HCL
Sensor Technology:3 electrode electrochemical cell
Measuring Range (ppm):HCI 0 – 8ppm
Minimum Alarm 1 Set Point:1ppm
Repeatability:< ± 10% of measured value
Linearity:< ± 20% of measured value
Response Time:t62.5 < 30 seconds based on 3 min. exposure t90 < 140 seconds based on 3 min. exposure
Sensor Cartridge Life Expectancy:24 months under typical application conditions

Operating Temperature:

Effect of Temperature

    Zero

    Sensitivity

0°C to +40°C (32°F to 104°F)

< ± 0.001ppm / °C (0°C to 20°C)

< ± 0.005ppm / °C (20°C to 40°C)

< ± 0.4% of measured value / °C

Operating Humidity:20 – 75% rH
Operating Pressure:90 – 110kPa
Effect of Position:No effect in typical application
Calibration Gas:Hydrogen Chloride (4-6ppm HCI)
Challenge Gas (Bump Test):Hydrogen Chloride (4-6ppm HCI)
Warm Up Time:< 20 minutes

 

 



Midas HCI Group Sensor Cartridge Spec Sheet

Products specifications
Attribute nameAttribute value
Gases DetectedBoron Trichloride (BCl3), Dichlorosilane (H2SiCl2), Hydrogen Bromide (HBr), Hydrogen Chloride (HCI)

Honeywell Midas Sensor Cartridge - Boron Trichloride (BCl3), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr), Hydrogen Chloride (HCl) 0.72-8 ppm

Detects 4 different types of gasses:
Boron Trichloride (BCl3 ), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr), Hydrogen Chloride (HCl)
Manufacturer: Honeywell
SKU: MIDAS-E-HCL
£241.00 excl vat £289.20 inc vat

Honeywell Midas Sensor Cartridge - Boron Trichloride (BCl3), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr), Hydrogen Chloride (HCl) 0.72-8 ppm

£241.00 excl vat £289.20 inc vat
Picture of Worldwide Shipping