Require Install, Commissioning, Calibration or Servicing?
Safety Gear Store are able to install, commission and service your fixed gas detection system. We offer a professional service from fully trained, certified and manufacturer approved engineers, we are also one of the only suppliers with engineers that carry spares in their vehicles to ensure a quick and efficient service that will enable you to continue using your facility.
For more information on what we offer please visit one of the below pages:
Fixed Gas Detection System Install and Commissioning
Fixed Gas Detection System Calibration and Servicing
Click Here to view all Crowcon Xgard Accessories.
Intrinsically Safe (I.S.) or Flameproof (Exd) versions are available, with case options comprising high-grade alloy, stainless steel or chemically resistant GRN polymer. Certifications include IECEx, ATEX, UL and GOST-R.
| Type 1 | Type 2 | Type 3 | Type 4 | Type 5 | Type 6 | |
| Size | 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) | 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) | 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) | |||
| Weight | Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) | Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs) | 1.5 kg (3.3lbs) | Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs) | ||
| Enclosure material | ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S | Aluminium or 316 Stainless Steel | Aluminium | Aluminium or 316 Stainless Steel | ||
| Ingress protection | IP65 | IP54 | IP65 | |||
| Cable entries | 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side | |||||
| Terminations | 0.5 to 2.5mm2 | |||||
| Sensor type | Electrochemical | Catalytic bead | 316 S/S sensor housing with catalytic beads | Catalytic bead | Thermal conductivity | |
| Operating temperature | -40 to +50 °C (-40 to 122 °F) (sensor dependant) | -20 to +50°C (-4 to 122°F) | -40 to +80°C (-40 to 176°F) | -20 to +150°C (-4 to 302°F) | -40 to +55°C (-40 to 131°F) | +10 to +55°C (50 to 301°F) |
| Humidity | 10 to 95% RH non-condensing | 0-99% RH non-condensing | 0-90% RH | |||
| Repeatability Zero drift | <2% FSD (Typical)<2% FSD per Month (Typical) | |||||
| Response time | T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant) | T90 <15s (Typical) | ||||
| Operating voltage | 8-30V dc | 2.0V dc +/- 0.1V (Typical) | 10-30V dc | |||
| Power requirements | 24mA maximum | 300mA (Typical) | 50mA at 24V dc 1.2W | |||
| Electrical output | 2- wire 4-20mA (current sink) | 3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4 | 3- wire mV bridgeTypical signal: >10mV/%LEL CH4 | 3- wire 4-20mA (current sink or source) | ||
| Approvals | ATEX: II 1 G Exia IIC T4 Ga (Tamb -40 to +55°C) UL/cUL: Class I, Div. 1 Groups A, B, C, D IECEx GOST-R | ATEX: II 2GD Exd IIC T6 Gb (Tamb -40 to +50°C) UL: Class I, Div. 1 Groups B, C, D IECEx GOST-R | ATEX: II 2 GD Exd IIC T4 Gb (Tamb -40 to +80°C) Exd IIC T6 Gb (Tamb -40 to +50°C) Ex tb IIIC T180°C Db UL: Class I, Div. 1 Groups B, C, D IECEx GOST-R | ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) | ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C) Exd IIC T4 Gb (Tamb -40 to +80°C) Ex tb IIIC T180°C Db UL: Class I, Div. 1 Groups B, C, D IECEx GOST-R | |
| EMC compliance | EN 50270 FCC Part 15 ICES- 003 | |||||
*3/4 ” cable entry only available on aluminium juntion boxes.
Sensors available are:
| Sensor Code | Description |
| SJ | Ammonia 0-1000ppm NH3 (-20C min) |
| SG | Ammonia 0-100ppm NH3 (-20C min) |
| AR | Ammonia 0-100ppm NH3 (-40C min) |
| SH | Ammonia 0-250ppm NH3 (-20C min) |
| SI | Ammonia 0-500ppm NH3 (-20C min) |
| SF | Ammonia 0-50ppm NH3 (-20C min) |
| AS | Arsine 0-1ppm AsH3 |
| AT | Bromine 0-3ppm Br2 |
| AM | Carbon monoxide 0-1000ppm CO |
| AI | Carbon monoxide 0-100ppm CO |
| AN | Carbon monoxide 0-2000ppm CO |
| AJ | Carbon monoxide 0-200ppm CO |
| AK | Carbon monoxide 0-250ppm CO |
| AL | Carbon monoxide 0-500ppm CO |
| AH | Carbon monoxide 0-50ppm CO |
| SE | Chlorine 0-100ppm Cl2 |
| SB | Chlorine 0-10ppm Cl2 |
| SC | Chlorine 0-20ppm Cl2 |
| SZ | Chlorine 0-3ppm Cl2 |
| SD | Chlorine 0-50ppm Cl2 |
| SA | Chlorine 0-5ppm Cl2 |
| AX | Chlorine dioxide 0-1ppm ClO2 |
| AY | Diborane 0-1ppm B2H6 |
| TC | Ethylene oxide 0-100ppm C2H4O |
| TA | Ethylene oxide 0-10ppm C2H4O |
| TB | Ethylene oxide 0-50ppm C2H4O |
| TD | Fluorine 0-1ppm F2 |
| AQ | Hydrogen 0-2000ppm H2 |
| AP | Hydrogen 0-200ppm H2 |
| TF | Hydrogen 0-40000ppm (0-100% LEL) H2 |
| SW | Hydrogen chloride 0-10ppm HCl |
| SX | Hydrogen chloride 0-25ppm HCl |
| SY | Hydrogen cyanide 0-25ppm HCl |
| AV | Hydrogen fluoride 0-10ppm HF |
| AG | Hydrogen sulphide 0-1000ppm H2S |
| AC | Hydrogen sulphide 0-100ppm H2S |
| TJ | Hydrogen sulphide 0-10ppm H2S |
| AD | Hydrogen sulphide 0-200ppm H2S |
| TK | Hydrogen sulphide 0-20ppm H2S |
| AE | Hydrogen sulphide 0-250ppm H2S |
| AA | Hydrogen sulphide 0-25ppm H2S |
| AF | Hydrogen sulphide 0-300ppm H2S |
| AB | Hydrogen sulphide 0-50ppm H2S |
| TI | Hydrogen sulphide 0-5ppm H2S |
| SP | Nitric oxide 0-100ppm NO |
| SN | Nitric oxide 0-25ppm NO |
| SO | Nitric oxide 0-50ppm NO |
| SM | Nitrogen dioxide 0-100ppm NO2 |
| SK | Nitrogen dioxide 0-10ppm NO2 |
| SL | Nitrogen dioxide 0-50ppm NO2 |
| HA | Ozone 0-1ppm O3 |
| TN | phosgene, 0-1ppm |
| TM | Phosphine 0-1ppm PH3 |
| TP | Silane 0-1ppm SiH4 |
| ST | Sulphur dioxide 0-100ppm SO2 |
| SQ | Sulphur dioxide 0-10ppm SO2 |
| SR | Sulphur dioxide 0-20ppm SO2 |
| SV | Sulphur dioxide 0-250ppm SO2 |
| SS | Sulphur dioxide 0-50ppm SO2 |
| TO | Volatile organics 0-100ppm VO |
| OA | Oxygen 0-25% vol O2 |
| Attribute name | Attribute value |
|---|---|
| Xgard Type | Xgard Type 6 |
| Gases Detected | Hydrogen (H2) |
Place a purchase order, call or email to get an international shipping quote
SECURED BY SECTIGO (We do not accept AMEX)
Call or email to speak to a member of the technical team
Safety Gear Store Ltd, Whittle road, Meir park, Stoke on Trent, Staffordshire, ST3 7TU