Require Install, Commissioning, Calibration or Servicing?
Safety Gear Store are able to install, commission and service your fixed gas detection system. We offer a professional service from fully trained, certified and manufacturer approved engineers, we are also one of the only suppliers with engineers that carry spares in their vehicles to ensure a quick and efficient service that will enable you to continue using your facility.
For more information on what we offer please visit one of the below pages:
Fixed Gas Detection System Install and Commissioning
Fixed Gas Detection System Calibration and Servicing
The product featured is:
| Analogue - No Relays | |
| FLP/A/A | 0-100% LEL with a VQ21T pellistor - gas types available methane, pentane, propane, butane, hexane, hydrogen, LPG, methanol, ethanol, propanol, ethylene, ethane, toluene, petrol vapour (unleaded) and carbon disulphide. |
Flamgard Plus is a Flameproof (Exd) flammable gas detector which uses poison-resistant pellistors to detect explosive levels of hydrocarbons, hydrogen and other flammable gases and vapours, including aviation fuel and leaded petrol vapours.
Gases & Ranges:
| Gas | LEL (% vol.) | Range Available |
| Acetylene (C2H2)* | 2.3 | 0-100% LEL |
| Ammonia (NH3) | 15 | 0-100% LEL |
| Butane (C4H10) | 1.4 | 0-100% LEL |
| Ethanol (C2H5OH) | 3.1 | 0-100% LEL |
| Ethane (C2H6) | 2.4 | 0-100% LEL |
| Ethylene (C2H4) | 2.3 | 0-100% LEL |
| Hexane (C6H14) | 1.0 | 0-100% LEL |
| Hydrogen (H2) | 4 | 0-100% LEL |
| LPG | 2 | 0-100% LEL |
| Methane (CH4) | 4.4 | 0-100% LEL |
| Methanol (CH3OH) | 6 | 0-100% LEL |
| Pentane (C5H12) | 1.1 | 0-100% LEL |
| Petrol vapor | 1.3 | 0-100% LEL |
| Propane (C3H8) | 1.7 | 0-100% LEL |
| Propanol (C3H8O) | 2.1 | 0-100% LEL |
Below is a small selection of the accessories available for the Flamgard Plus.
Spray deflector - C01052 - For use outdoor installations and to protect from water sprays, for example in water treatment or food processing plants. For extremely wet environments eg: offshore installations, use weatherproof cap, CO1442, instead.
Weatherproof cap - C01442 - For offshore or other extremely wet environments in place of spray deflector.
Collector cone - C01051 - For aiding detection of light gases such as methane. 38cm/15″ Dia. Includes accessory adaptor.
Stainless steel flow adaptor - C016188 - For use where a gas sample is being piped to the detector. For 96HD type sensors.
Self adhesive carbon cloth filter - C01254 - Removes long chain hydrocarbons where these can be a problem.
Exd Cable Gland Adaptors - ATEX certified Exd cable gland adaptors.
Exd/Exe Certified Brass Cable gland - M02354 - Suitable for Steel Wire Armoured cables with outside diameter 15.5mm to 21.1mm (inner sheath 6.7mm to 14mm). Certified to ATEX (ll 2DG, Exd llC/Exe ll), IECEx, CSA, GOST-R and NEPSI standards. M20 x 1.5mm thread. Ingress protection to IP66/67/68.
Calibration adaptor - C03005 - To enable calibration gas to be applied to the detector. One adaptor can be used for several detectors.
| Product Code | Description |
| Analogue - No Relays | |
| FLP/A/A | 0-100% LEL with a VQ21T pellistor - gas types available methane, pentane, propane, butane, hexane, hydrogen, LPG, methanol, ethanol, propanol, ethylene, ethane, toluene, petrol vapour (unleaded) and carbon disulphide. |
| FLP/G/A | 0-100% LEL with VQ41 pellistor - ammonia (0-25%, 0-100% LEL) or jet fuel (0-100% LEL) |
| With Relays | |
| FLP/A/R | 0-100% LEL with VQ21T pellistor - gas types available methane, pentane, propane, butane, hexane, hydrogen, LPG, methanol, ethanol, propanol, ethylene, ethane, toluene, petrol vapour (unleaded) and carbon disulphide. |
| FLP/G/R | 0-100% LEL with VQ41 pellistor - ammonia (0-25%, 0-100% LEL) or jet fuel (0-100% LEL) |
| No Sensor | |
| FLP-0077 | Flamgard-Plus without sensor assembly, ATEX M20 |
| FLP-0022 | Flamgard-Plus without sensor assembly, with relays. ATEX M20 |
| FLP-0069 | Flamgard-Plus without sensor assembly UL 1/2"NPT |
| FLP-0041 | Flamgard-Plus without sensor assembly, with relays. UL 1/2"NPT |
| Without relays | |
| FLP-06 | Methane 0-100% LEL, No Relays, M20, ATEX |
| FLP-08 | Hydrogen 0-100% LEL, No Relays, M20, ATEX |
| FLP-09 | LPG 0-100% LEL, No Relays, M20, ATEX |
| FLP-10 | Propane 0-100% LEL, No Relays, M20, ATEX |
| With relays | |
| FLP-01 | Methane 0-100% LEL, Relays, M20, ATEX |
| FLP-02 | Butane 0-100% LEL, Relays, M20, ATEX |
| FLP-03 | Hydrogen 0-100% LEL, Relays, M20, ATEX |
| FLP-04 | LPG 0-100% LEL, Relays, M20, ATEX |
| FLP-05 | Propane 0-100% LEL, Relays, M20, ATEX |
| Attribute name | Attribute value |
|---|---|
| Gases Detected | Methane (CH4), Pentane (C5H12), Propane (C3H8), Butane (C4H10), Hexane (C6H14), Hydrogen (H2), Combustible Gases, Methanol (CH3OH), Ethanol (C2H5OH), Ethylene (C2H4), Ethane (C2H6), Toluene (C7H8), Carbon Disulphide (CS2), Ammonia (NH3) |
Place a purchase order, call or email to get an international shipping quote
SECURED BY SECTIGO (We do not accept AMEX)
Call or email to speak to a member of the technical team