Require Install, Commissioning, Calibration or Servicing?
Safety Gear Store are able to install, commission and service your fixed gas detection system. We offer a professional service from fully trained, certified and manufacturer approved engineers, we are also one of the only suppliers with engineers that carry spares in their vehicles to ensure a quick and efficient service that will enable you to continue using your facility.
For more information on what we offer please visit one of the below pages:
Fixed Gas Detection System Install and Commissioning
Fixed Gas Detection System Calibration and Servicing
Product featured is the oxygen sensor module 0-25%, 2-year life please call saled for other options
The new XgardIQ, our most intelligent fixed-point gas detector, increases safety by minimising the time operators must spend hazardous areas. This versatile transmitter and gas detector has a range of features that protect engineers and support facilities managers of oil, gas, chemical & petrochemical plants to name a few.
Available fitted with a variety of flammable, toxic or oxygen gas sensors.
XgardIQ is an intelligent and versatile gas detector and transmitter compatible with Crowcon’s full range of sensor technologies. Available fitted with a variety of flammable, toxic or oxygen gas sensors. Providing analogue 4-20mA and RS-485 Modbus signals as standard, XgardIQ is optionally available with Alarm and Fault relays and HART communications. The 316 stainless steel are available with three M20 or 1/2“NPT cable entries.
Easy and safe to use
| Size | H278 x W140 x D89mm (10.9 x 5.5 x 3.5 in) |
| Weight | 4.1Kg (9lbs) |
| Enclosure material | 316 stainless steel |
| Ingress protection | IP66 |
| Connection | Three M20 or ½”NPT cable gland entries.Certified, removable plugs are fitted to left-hand and lower righthand entries |
| Power | 14-30 VDC. <4W |
| Display | Main display – OLED 128 x 64 pixels, yellow text on black background Indicators – Amber, Red and Green LED’s for detector status; Blue +ve Safety LED |
| Electrical output | 4-20mA current sink or source (Auto-Sense or manual selection); warning and fault signals are configurable. NAMUR NE 43 compliant RS-485 Modbus RTU HART 7 over 4-20mA signal and via local I.S. test points (optional) Foundation Fieldbus (option pending, contact Crowcon) Relays (optional) Alarm 1, Alarm 2, Fault SPCO contacts rated 5A, 230Vac Relay configuration options Energised or de-energised Latching or non-latching Rising or falling Configurable On and Off delays on alarm relays. |
| Event logging | Records alarm, fault and maintenance events. Events can be viewed on-screen and downloaded to a PC. |
| Operating temperature | Transmitter only: -40°C to +75°C (-40°F to +167°F)† Sensor type: Oxygen: (-20°C to +50°C ambient) |
| Humidity | 0 to 95% RH non-condensing† |
| Repeatability | +/- 2% FSD |
| Zero drift | +/- 2% FSD per year maximum |
| Response time | Sensor dependant: contact Crowcon for specific sensor data. |
| Approvals | ATEX and IECEx: Ex II 2 G Ex db ia IIC T4 Gb (see above for temperature ranges) |
| Performance | Designed for compliance with: EN60079-29-1 (flammable gas sensors)* EN50104 (oxygen sensors)* EN45544 (toxic gas sensors)* |
| Functional safety | IEC61508, EN50402 SIL 2* |
| EMC Compliance | EN50270:2015 FCC CFR47 Part 15B ICES-003 |
Note: sensor operating temperature and humidity limits vary widely.
* Features outstanding at the time of issue, contact Crowcon for details.
Gases and Ranges:
| Gas | Units | Max Range | Standard Range | Alarm 1 level | Alarm 2 level | Temp range °C |
| Oxygen (O2) | %Vol | 30 | 25 | 19 (falling) | 17 (falling) | -20 to +50 |
| Ammonia | PPM | 100/1000 | 50 | 25 | 35 | -20 to +40 |
| Carbon Monoxide (CO) | PPM | 1000 | 250 | 30 | 200 | -30 to +50 |
| Hydrogen Fluoride (HF) | PPM | 10 | 10 | 1.8 | 3 | +5 to +40 |
| Hydrogen Sulphide (H2S) | PPM | 100/200 | 25 | 5 | 10 | -30 to +50 |
| Mercaptan (CH3SH) | PPM | 14 | 14 | 5 | 10 | -10 to +40 |
| Ozone (O3) | PPM | 1 | 1 | 0.1 | 0.2 | -20 to +40 |
| Sulphur Dioxide (SO2) | PPM | 100 | 10 | 1 | 1 | -30 to +50 |
| Hydrogen (H2) | %LEL | 100 | 100 | 20 | 40 | -40 to +75 |
| Methane (CH4) | %LEL | 100 | 100 | 20 | 40 | -40 to +75 |
| Pentane (C5H12) | %LEL | 100 | 100 | 20 | 40 | -40 to +75 |
| Propane (C3H8) | %LEL | 100 | 100 | 20 | 40 | -40 to +75 |
| Ethanol (IR sensor) | %LEL | 100 | 100 | 20 | 40 | -20 to +55 |
| LPG (IR sensor) | %LEL | 100 | 100 | 20 | 40 | -20 to +55 |
| Methane (IR sensor) | %LEL | 100 | 100 | 20 | 40 | -20 to +55 |
| Propane (IR sensor) | %LEL | 100 | 100 | 20 | 40 | +10 to + 55 |
Accessories:
Below is a small selection of the accessories available for the XgardIQ.
Place a purchase order, call or email to get an international shipping quote
SECURED BY SECTIGO (We do not accept AMEX)
Call or email to speak to a member of the technical team